Sales PortalSpecification SheetsCross-ReferenceRFQ BuilderDownloads & Catalogs
+86 159 5875 8125|
Get a Quote
Product line

Duplex Receptacles

Eight devices for the standard wall outlet — duplex and decorator faces, 15A and 20A, TR and TR/WR, all UL/cUL listed.

8Models in this line
UL / cULListed (see per-model data)
15A / 20A125V AC · NEMA 5-15R / 5-20R
7Finish options
8 of 8 models
15A Standard Duplex Receptacle Non-TR15A Standard Duplex Receptacle Non-TR — another angle15A

15A Standard Duplex Receptacle Non-TR

TMDR15 · 5-15R
Standard face
15A Tamper-Resistant Duplex Receptacle15A Tamper-Resistant Duplex Receptacle — another angle15A

15A Tamper-Resistant Duplex Receptacle

TDT15 · 5-15R
TR
15A TR/WR Duplex Receptacle15A TR/WR Duplex Receptacle — another angle15A

15A TR/WR Duplex Receptacle

TDTW15 · 5-15R
TRWR
20A Standard Duplex Receptacle NEMA 5-20R20A Standard Duplex Receptacle NEMA 5-20R — another angle20A

20A Standard Duplex Receptacle NEMA 5-20R

TMDR20 · 5-20R
Standard face
20A Tamper-Resistant Duplex Receptacle20A Tamper-Resistant Duplex Receptacle — another angle15A

20A Tamper-Resistant Duplex Receptacle

TDT20 · 5-15R
TRWR
20A TR/WR Duplex Receptacle20A TR/WR Duplex Receptacle — another angle20A

20A TR/WR Duplex Receptacle

TDTW20 · 5-20R
TRWR
15A Standard Decorator Receptacle (Non-TR)15A Standard Decorator Receptacle (Non-TR) — another angle15A

15A Standard Decorator Receptacle (Non-TR)

TMSR15 · 5-15R
Decorator face
20A Standard Decorator Receptacle20A Standard Decorator Receptacle — another angle20A

20A Standard Decorator Receptacle

TMSR20 · 5-20R
Decorator face
What this line covers

The outlet that a project schedule lists most often

A duplex receptacle is the highest-count device on almost every electrical schedule, which makes it the line where a small unit-price difference is worth the most. This line covers the two faces a specification asks for — the traditional duplex and the decorator — in 15A and 20A, with and without tamper-resistant shutters and with a weather-resistant construction for damp locations.

What the models share is deliberate: thermoplastic face and body, brass / green / silver terminals, side and back wiring, a grounding path, and a plate included with the device. What changes is the face, the rating, and the shutter and gasket construction the location calls for. The finishes come from one palette across the whole line, so a unit turn does not read as a patchwork of whites by room.

The two faces are not interchangeable at the plate. A duplex receptacle takes a duplex plate with two openings and a centre screw; a decorator receptacle takes a large rectangular decorator opening and top-and-bottom screws. Both plate types are in the Wall Plates line, and mixing them is the single most common ordering error on this page.

Ratings15A / 20A · 125V AC · NEMA 5-15R / 5-20R
FacesTraditional duplex and decorator (rectangular)
ShuttersTamper-resistant (TR) available; non-TR models are the standard versions
Weather-resistantTR/WR construction for outdoor, damp and wet locations
Body and face materialThermoplastic
TerminalsSide and back wire · brass hot, silver neutral, green ground
GroundingYes — self-grounding clip on the grounded models
Wall plateIncluded with the device
Finish rangeWhite, black, ivory, almond, grey, brown, graphite
Selection guide

Four decisions, and three of them are on the drawing

The face, the rating and the shutter requirement come from the drawing and the code edition. The colour comes from the interior package. Everything else is a sourcing decision.

What the schedule saysWhat to put on the POWhy buyers get this wrong
Dwelling units, guest rooms, dorms15A TR decorator or duplex — TDT15 (duplex) or TMSR15 face where the spec is decoratorNon-TR models still ship into projects where NEC 406.12 applies. The inspector catches it, not the buyer.
Kitchen, laundry, garage and shop circuits20A T-slot duplex — TMDR20, or TDTW20 where the location also needs the WR construction20A is a branch-circuit decision, not an upgrade. The face has to match the circuit either way.
Exterior walls, patios, covered porchesTR/WR — TDTW15 / TDTW20, plus the correct coverWR is not waterproof. The receptacle is half the assembly and the cover is the other half — and the cover is a separate line.
Hospitality and multifamily unit turnsOne face, one finish, one plate type across the floorBuying duplex in one room and decorator in the next is what makes a refurbished floor look patched.
Distributor shelf stock15A TR and 20A TR as the two base SKUs, WR and non-TR as depthStocking every combination ties up cash; the two TR faces cover most counter demand.
Three combinations that come back as returns
  • Decorator receptacle ordered against a duplex plate. The plate opening and the mounting screws are different. If the plate schedule is already printed, order the receptacle to the plate and not the other way round.
  • WR receptacles specified without the cover line. The device will be correct and the install still fails the damp-location requirement. Ask for the cover and the box on the same PO.
  • A 15A and a 20A face on the same schedule with one part number. They are different devices with different openings. If the schedule does not distinguish them, the quote will come back with the TR 15A assumption flagged in writing rather than guessed.
Listings & documents

What we can put in front of an inspector

These are the documents we hold for the line and can send with a quotation. Where a model carries a qualification in the source data — that is, the listing is confirmed for that device and not just for the family — we say so on the line item rather than on the page.

  • UL/cUL listing for the listed models — the certification is recorded per model in our product data, so the quotation names the devices it covers.
  • Specification sheets per model with rating, face, shutter and terminal data transcribed from the same source as this page.
  • Plate and cover cross-reference — which plate opening and which cover go with each face, so the schedule and the plate order agree.
  • Packing and carton marking detail — case pack, carton dimensions and barcode layout for DC receiving on high-count orders.
  • Sample program — working samples before production where a property engineer or contractor has to approve the device.

Non-TR models are a legitimate product for exempt applications and are listed here as such — but we do not present them as a safe substitute for TR in housing. If the project type is unclear we will quote TR and flag the assumption in writing.

For high-count orders

Send the device schedule by room type and floor. We will return the model list, the face and finish per line, the plate cross-reference, and the carton count — which is usually the number that decides who wins the bid.

Send a device schedule →
Before the first order

Procurement questions we get asked most

Are these devices UL listed?

The listed models are recorded as UL/cUL listed in our product data, and the quotation names the devices the certification covers. Where a line item does not carry a qualification in our data we will not present it as listed — ask and we will confirm per model before the order.

What is the difference between the duplex and the decorator models?

The face opening, and therefore the plate: the duplex face takes a plate with two separate outlet openings and a centre screw, while the decorator face takes a large rectangular opening with top and bottom screws. Electrically they are the same class of device.

Can 15A and 20A ship in the same carton?

They are different faces, so they are packed and labelled as separate line items. They can share the pallet, the container and the paperwork, which is normally what a DC wants anyway because the receiving scan is per SKU.

How many finishes can I mix in one order?

Devices and plates are drawn from one palette, and the models in this line are published with the same set of finishes. Availability is confirmed per model when you quote, so lock the colour with the model list rather than after production starts.

Do the devices come with plates and screws?

Yes — the plate is part of the device line item for this range and the mounting screws ship with it. Where a distributor programme needs the plates packed separately, that is a packaging instruction on the order rather than a second purchase.

What is the lead time from PO to loading?

Production runs 25–35 days depending on the mix and the colour confirmation, and samples are around five working days. The two variables that move the date are colour confirmation and packaging artwork approval.

Can’t decide from photos

Put them next to each other

Tick any models in the comparison tool and only the differences get highlighted — amperage, NEMA configuration, face type, TR/WR construction, finish range. Then send the shortlist as one RFQ.

Open model comparison →
Request a quote

Send the list, get the package back

Model list, quantities and project type is all we need to start. The quotation comes back in one business day with the specification sheet for each line item, the listing reference it holds and the packing detail for the DC — one document, not four.

Prefer email? sales@syoutlet.com

Reply in 1 business day · no minimum quoted, MOQ follows the container you book