Solutions · Outdoor & Wet Locations

Weather-resistant where the wall faces the weather

TR/WR self-test GFCI and TR/WR duplex devices for exteriors, laundry walls and commercial washrooms.

TR + WRBoth ratings, one device
Class A5mA ±1mA trip
5-15R / 5-20R15A and 20A
UL 943Listed GFCI family
What this setting demands

The four decisions behind every outdoor & wet locations order

Each one is a line on the drawing and a line on the quote — stated against the code or the rating that puts it there.

Weather-resistant is a separate rating from GFCI

A device can be GFCI and not weather-resistant. Exterior and damp walls need both, which is why the TR/WR models carry both ratings in one yoke and state it on the face.

WRTRUL 943 Class A

Exterior receptacles are a cover question as well

The device is only half of the installation: a listed weather-resistant cover is required at outdoor locations. We supply the device; the cover has to be specified with it, and it is not part of our current range.

Cover requiredNot in our range

Laundry and utility walls sit in the damp zone

Laundry, utility and mechanical walls are the interior locations that go TR/WR rather than plain TR. Specifying one model across them keeps the device list short.

Damp locationTR/WR

Wet walls need maintenance-free protection

Exterior and washroom GFCI is exactly where nobody tests monthly. Self-test monitoring flags end-of-life on the LED so a failed device is visible on a walkthrough instead of discovered by a resident.

Self-TestNEC 210.8(B)
Specified devices

Device schedule for outdoor & wet locations

Placement to part number to the reason it fits — every model below is in the catalog with its amperage, NEMA configuration and TR/WR status on the spec sheet.

PlacementDeviceWhy this model
Exterior wall and patioWTST15 / WTST20Self-test GFCI, TR + weather-resistant, NEMA 5-15R or 5-20R
Garage, laundry and utility wallTDTW15 / TDTW20TR/WR duplex, 15A or 20A, NEMA 5-15R / 5-20R
Commercial washroomTST15 / TST20Self-test GFCI with TR shutters for indoor wet-room walls
Exterior lighting controlTM-415A 120/277V rocker for exterior and mechanical circuits
Cover plate, outdoor location—Listed weather-resistant cover required with the device — not in our current range

Four of the models on this schedule. The full range is 54 SKUs across five families.

In the field

Scene gallery

A multi-storey exterior wall — the kind of façade run where WR devices
A multi-storey exterior wall — the kind of façade run where WR devices are specified and the cover requirement is decided.
A TR/WR device checked against the spec sheet before dispatch, with th
A TR/WR device checked against the spec sheet before dispatch, with the amperage and NEMA configuration on the paperwork.
Exterior and utility wall devices laid out for a project list: TR/WR s
Exterior and utility wall devices laid out for a project list: TR/WR status read per line rather than assumed.

Scene photography is representative. Ask your sales engineer for project-specific photos or a live walkthrough of the settings you are specifying for.

Installation notes
  • WR and TR are separate ratings — the catalog states both per model, and our TR/WR models carry each on the face.
  • Exterior installations need a listed weather-resistant cover; we do not currently supply covers, so that line is marked for confirmation.
  • Self-test GFCI is the maintenance answer for exterior and washroom locations that nobody tests monthly.
  • Both 15A and 20A TR/WR devices are stocked so the exterior line matches the branch circuit.
  • Devices ship with the matching wall plate; outdoor cover assemblies are a separate purchase.
Procurement

Exterior and wet-location orders usually combine devices and covers from different suppliers.

  • TR/WR GFCI and duplex devices in 15A and 20A, mixed with the rest of the device list.
  • Seven finishes for plates on covered exterior locations.
  • Sample units for the authority or inspector review.
Purchasing FAQ

Outdoor & Wet Locations questions we get before the PO

Is a GFCI automatically weather-resistant?

No. Ground-fault protection and weather resistance are separate ratings. The WTST15 / WTST20 models carry both TR and WR ratings in one device for exterior and damp locations.

What is required at an outdoor receptacle?

A listed weather-resistant cover is required at outdoor locations in addition to a WR-rated device. We supply the device; covers are outside our current range and are specified separately.

Which interior locations need WR devices?

Damp interior locations such as laundry, utility and mechanical walls typically go TR/WR. TDTW15 and TDTW20 are the TR/WR duplex models for those walls.

Do you have 20A weather-resistant devices?

Yes — WTST20 (GFCI) and TDTW20 (duplex) are the 20A TR/WR models, both on NEMA 5-20R.

How do I confirm the exterior rating for a submittal?

Every line comes back with amperage, NEMA configuration and TR/WR status stated per model, which is the data a submittal package needs. Any additional exterior documentation is supplied with the quotation when it exists.

Request a quote

Send the list, get the package back

Model list, quantities and project type is all we need to start. The quotation comes back in one business day with the specification sheet for each line item, the listing reference it holds and the packing detail for the DC — one document, not four.

Prefer email? sales@syoutlet.com

Reply in 1 business day · no minimum quoted, MOQ follows the container you book