Click to enlarge7 factory photos of this exact model · shot on our Lishui line, no renders. Click a thumbnail to change the main image.
15A Weather-Resistant Self-Test GFCI Receptacle
15A 125V ground-fault receptacle with a NEMA 5-15R face. It is built as a Class A self-test GFCI — the device checks its own protection circuit and locks out the reset if that check fails. The face is tamper-resistant, so the shutters stay closed unless both slots are pressed at once. The body carries the weather-resistant construction for damp and wet locations — the cover is a separate line item.
Part of the Class A self-test GFCI line — UL 943 Ed. 6 construction, 5 mA ±1 mA trip level, automatic self-test with reset lockout on failure.
| Amperage | 15A |
|---|---|
| Voltage | 125V |
| NEMA | 5-15R |
| GFCI Type | Self-Test GFCI, Class A GFCI |
| Trip Level | 5mA ±1mA |
Send the quantity, the project type and the colour. Quotation in one business day with the specification sheet, the listing reference for this model and the packing detail for the DC.
What WTST15 is, and what you get
15A 125V ground-fault receptacle with a NEMA 5-15R face. It is built as a Class A self-test GFCI — the device checks its own protection circuit and locks out the reset if that check fails. The face is tamper-resistant, so the shutters stay closed unless both slots are pressed at once. The body carries the weather-resistant construction for damp and wet locations — the cover is a separate line item.
Part of the Class A self-test GFCI line — UL 943 Ed. 6 construction, 5 mA ±1 mA trip level, automatic self-test with reset lockout on failure.
- Confirm TR or non-TR before ordering — NEC 406.12 applies to dwelling units and public spaces.
- On WR models the receptacle is half the assembly: the cover and the box are separate lines.
- GFCI + USB models take a decorator opening and a deeper wall box — confirm the box before the order.
- Automatic self-test monitoring helps verify GFCI protection status
- UL/cUL listed under the UL 943 Class A GFCI framework with a 5mA ±1mA trip level
- WR and TR construction supports outdoor and public-facing applications that require both weather resistance and tamper-resistant protection
- Standard 15A receptacle configuration with contractor-oriented installation use
- 7 standard colors — White, Black, Ivory, Almond, Grey, Brown, Graphite
- Use with a listed extra-duty in-use cover where required for wet locations
Every field we hold for WTST15
Transcribed from the product data the quotation is generated from — grouped for review, not edited. Values are published as they stand, including the ones still marked for confirmation.
| Certified Safety | UL, cUL |
|---|---|
| Standards & Certifications | UL/CSA, NEMA WD6 |
| Own US Patents | Yes |
| Country of Origin | China |
| GFCI Type | Self-Test GFCI, Class A GFCI |
|---|---|
| Voltage | 125V |
| Amperage | 15A |
| NEMA | 5-15R |
| Operating Temperature | -35C to 66C(-30F to 150F) |
| Pole | 2 |
| Wire | 3 |
| Number of Receptacles | 2 |
| Trip Level | Class A, 5mA ±1mA |
| Safety Function | Automatic self-test monitoring |
| Tamper Resistant | Yes |
| Weather Resistant | Yes |
| Color | White,Ivory,Almond,Black,Grey,Brown,Graphite |
|---|---|
| Finish | Satin |
| Features | Alarm, Self-Test |
| Face Material | Thermoplastic |
| Body Material | Thermoplastic |
| Wiring Method | Back Wire and Side Wire |
|---|---|
| Grounding | Self Grounding |
| Terminal | Brass-Hot, Green-Ground, Silver-Neutral |
| Application Sector | Commercial, Multi-Dwelling Unit, Residential |
|---|
| Product Code | WTST15 |
|---|---|
| Wall Plate Included | Yes |
| NEMA Configuration | 5-15R |
|---|---|
| GFCI Class | Class A |
| Self-Test | Yes |
| Application | Outdoor / Damp / Wet Locations |
Use this one, or step to another
- Contractors sourcing outdoor 15A GFCI replacements
- Distributors building WR / TR GFCI inventory
- Property management buyers handling apartment and condo exterior upgrades
- Project buyers who need a standard 15A outdoor GFCI rather than a 20A T-slot device
- Choose a 20A WR GFCI receptacle when the project requires a NEMA 5-20R / 20A device format rather than a standard 15A receptacle. WTST20 — 20A Weather-Resistant Self-Test GFCI Receptacle
- Choose an indoor TR GFCI receptacle when the installation does not require weather-resistant construction. TST15 — 15A Tamper-Resistant Self-Test GFCI Outlet
- Choose a non-TR WR GFCI receptacle only when the installation location does not fall within the tamper-resistant receptacle requirements that apply to specified 15A and 20A nonlocking receptacle locations. TS15 — 15A Non-Tamper Resistant Self-Test GFCI Receptacle
WTST15 on camera
Watch on YouTubeUL Listed 20A&15A GFCI Receptacle with Screwless Plate | B2B Wholesale
How to Install a 15A WR GFCI Receptacle
The plate for this device is T9603 1-Gang Decorator Receptacle Wallplate. Order the plate with the device so the opening, the face and the finish arrive on the same delivery — and confirm the wall box depth on any combination or fast-charge model before installation day.
Where WTST15 is specified
What ships with the quotation
- SY Outlet product catalogPDF · the full 54-model catalogOpen
- GFCI receptacle wiring guidePDF · wiring guideOpen
- Product videoOn our YouTube channelWatch
- Specification sheet for WTST15Issued with the quotation, generated from the data on this pageOn request
- Specification sheet per model with the electrical data, face construction and terminal information transcribed from the same source as this page.
- Listing reference for the exact model, named on the quotation rather than claimed at line level.
- Wiring and box-fill detail — LINE/LOAD terminals, back-wire and side-wire capacity, and the cover requirement on WR models.
- Packing and carton marking — case pack, carton dimensions and barcode layout for DC receiving on mixed orders.
Packaging as published: case pack per model, issued with the quotation · country of origin: China
WTST15 — answered
Is the WTST15 a self-test device, or do I have to test it myself?
Every model in this line is self-test. The device runs an automatic periodic check of its own protection circuit and, if that check fails, locks out the reset — so a failed GFCI cannot be reset and left in service. On the UL 943 framework the self-test is a requirement, not an upgrade, and it removes the monthly manual test that nobody in a guest room or a rental ever performs.
Why does the WTST15 feel tighter when I push a plug in?
Because it is tamper-resistant. The shutters stay closed unless both slots are pressed at the same time, which is what makes a TR receptacle feel firmer than a standard outlet. NEC 406.12 requires listed TR receptacles in dwelling units, guest rooms, education and child-care facilities and similar occupancies — the tightness is the feature, not a defect.
Is WTST15 waterproof?
It is weather-resistant, not waterproof. The WR construction covers the device itself for the damp and wet locations described in NEC 406.9, and the device is only half of that assembly — the cover and the box are separate line items. Ordering the WR rating without the cover is the most common way a damp-location install fails inspection.
Can a 15A device go on a 20A circuit?
A 15A receptacle is permitted on a 20A branch circuit where the circuit serves two or more receptacles — that is NEC 210.21(B)(3), and it is normal practice in commercial and multi-unit work. What is not interchangeable is the face geometry: a NEMA 5-20R device on a 15A circuit fails the same inspection the other way round. Confirm the circuit design rather than the look of the device.
Does the GFCI protect the outlets downstream on the same circuit?
Yes, when the LOAD terminals are used: the hot and neutral feeding the downstream devices land on the brass and silver LOAD terminals and everything beyond them is protected by this device. Reversing LINE and LOAD is the error that shows up as a GFCI that trips as soon as a downstream load is plugged in — and it silently removes the downstream protection as well.
What do you need from me to quote a mixed order?
The model list with quantities, the project type, the colour and the plate schedule. The quotation comes back in one business day with the specification sheet for each line item, the listing reference it holds and the packing detail for the DC — one document rather than four.
Answers above are specific to WTST15; the model list, quantities and project type is what we need to quote it back in one business day.
Send the list, get the package back
Model list, quantities and project type is all we need to start. The quotation comes back in one business day with the specification sheet for each line item, the listing reference it holds and the packing detail for the DC — one document, not four.
WhatsApp / Mobile +86 159 5875 8125Prefer email? sales@syoutlet.com
15A Non-Tamper Resistant Self-Test GFCI Receptacle
15A Tamper-Resistant Self-Test GFCI Outlet
15A Self-Test TR GFCI Receptacle with USB-A and USB-C
15A Combination USB GFCI Receptacle with Dual USB-A